Procedure
............................................................................................................................................................
1
Identify the QPHPIPE/5828 office records with SERVICE equal to
SIPT. At the MCC or TLWS type and enter the command:
OP:OFR:FORM=5828;
Result:
OP OFR FORM=5828 PF is printed followed by a printout
of the QGCON/5828 office records.
Make a note of the GQPH pipes that have SIP-T service.
............................................................................................................................................................
2
Deactivate each GQPH pipe identified as having SIP-T service in step
1.
RMV:GQPHPIPE=a-b-c-d-e,ucl;
Result:
The RMV GQPHPIPE report is printed and the GQPH pipe
is deactivated.
............................................................................................................................................................
3
Select and prepare terminal for RC/V activities.
Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
4
Type and enter the RC/V form number.
17.24
Result:
Enter Database Operation I=Insert,R=Review,D=Delete:
............................................................................................................................................................
5
Type and enter the delete command.
D
Result:
The QPH PIPE ASSIGNMENT page is displayed and the cursor
is located at the GLOBAL SM field.
............................................................................................................................................................
6
Using the RC/V 17.24 form as a guide, type and enter the parameters
for the GQPH pipe.
*GLOBAL SM
*PSU SHELF
Delete All SIP GQPH Pipes (RC/V 17.24)
Deprovisioning
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
6-73

Table of Contents