Delete All SCTP Near Endpoints (RC/V 33.19)
....................................................................................................................................................................................................................................
Purpose
The SCTP Endpoint (RC/V 33.19) view is used to delete the SCTP
near endpoints to a processor group.
When to use
Use this procedure to delete the near SCTP endpoints.
Related information
Refer to 235-118-258, Recent Change Reference for information on
the RC/V system.
Refer to the 235-600-700/750, Input/Output Messages manuals for
additional information on the Input and Output commands.
Admonishments
None.
Before you begin
Required Tools
Supplemental Trunk Line Workstation (STLWS) or Recent
Change and Verify (RC/V) terminal
Access to RC/V Menu Interface
Required Material
The 5ESS
®
switch must be running a 5E16.2 FR3 software
release or later with the SIP for Packet Trunking - NAR feature
software.
Required Information
All SCTP Near Endpoint names
Required Conditions
All SCTP associations have been deleted on RC/V 33.22
Procedure
............................................................................................................................................................
1
Identify the SCTP near endpoints to delete.
Enter the command:
OP:STATUS,SCTP,NEAREPT,ALL;
Result:
The OP STATUS SCTP NEARPT report is printed. The
status of each near endpoint is GROW, indicating
that the required condition that all SCTP
associations have been deleted on RC/V 33.22 has
been met.
Deprovisioning
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
6-41