Change SIP Parameters
....................................................................................................................................................................................................................................
Purpose
The SIP-T Parameters Definition view (RC/V 5.82) is used to change
the SIP parameter definitions.
When to use
Use this procedure to change a SIP parameter set.
Related information
Refer to 235-118-258, Recent Change Reference, for information on
the RC/V system.
Admonishments
None.
Before you begin
Required Tools
• Supplemental Trunk Line Workstation (STLWS) or Recent
Change and Verify (RC/V) terminal
• Access to RC/V Menu Interface
Required Material
• The 5ESS
®
switch must be running a 5E16.2 FR3 software
release or later with the SIP for Packet Trunking - NAR feature
software.
Required Information
• SIP Parameter set name
Required Conditions
• If this RC/V view is being updated to support
SIP without
Encapsulated ISUP
, the 5E-XC
™
must be running on software
release 5E16.2 FR6 or later. In addition, SFID 769 must be
activated prior to executing this procedure. To activate a secured
feature refer to “Feature Activation (RC/V 8.22)” (5-13).
Procedure
............................................................................................................................................................
1
Select and prepare terminal for RC/V activities.
Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
2
Type and enter the RC/V form number.
Provisioning
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
5-147