Add SCTP Associations to Existing Association Set
....................................................................................................................................................................................................................................
Purpose
This section defines the procedure for adding an SCTP association to
an existing association set.
When to use
Use this procedure to add an SCTP association to an existing
association set.
Related information
Refer to 235-118-258, Recent Change Reference, for information on
the RC/V system.
Refer to the 235-600-700/750, Input/Output Messages manuals for
additional information on the Input and Output commands.
Admonishments
None.
Before you begin
Required Tools
• Supplemental Trunk Line Workstation (STLWS) or Recent
Change and Verify (RC/V) terminal
• Access to RC/V Menu Interface
Required Material
• The 5ESS
®
switch must be running a 5E16.2 FR3 software
release with the SIP for Packet Trunking - NAR feature software.
Required Information
• Association number
• Packet Group
Required Conditions
• None
Procedure
............................................................................................................................................................
1
Use OP:STATUS,SCTP,ASSOC and/or read RC/V 33.22 for the
association to verify that it is not already part of an association set,
and is in the CLOSED MAN state, or execute the “Add New SCTP
Association to Connect to a SCTP Far Endpoint” (5-102) procedure.
............................................................................................................................................................
2
Use RC/V 33.23 to add the association to the association set.