Request Internet Protocol (IP) Configuration Data
....................................................................................................................................................................................................................................
Purpose
This procedure requests IP address configuration data to be displayed.
When to use
According to local routine maintenance practices, use this procedure
to verify IP address configuration data. For example, if growing a SIP
PH, check for IP address duplication against existing IP address
configuration data.
Related information
Use Office Records 5987, 5988, and 5995 for off-line analysis. Refer
to the Input Messages Manual, 235-600-700 and the Output Messages
Manual, 235-600-750, for additional information.
Admonishments
An enormous amount of data may be printed on the Receive-only
Printer (ROP). The use of any format could cause a degradation in
switch service. You may want to list the office records that can be
examined off-line. However, the printing of this data may be stopped
using STP:IPCFG should system operation be impacted.
Before you begin
Required Tools
• Use of Master Control Center (MCC) or Supplementary Trunk
Line Workstation (STLWS).
Required Material
• The switch must be running a 5E16.2 FR3 software release or
later with the SIP for Packet Trunking feature software.
Required Information
• Associated SM number
• IP Address
• Network ID
Required Conditions
• None required.
Procedure
............................................................................................................................................................
1
Request IP address configuration data for an office:
OP:IPCFG,OFFICE;
Result:
Displays IP address configuration data for the office.
Maintenance Considerations
....................................................................................................................................................................................................................................
7-28
Lucent Technologies 235-200-118
Issue 3.02B, March 2007