EasyManua.ls Logo

Lucent Technologies 5ESS - Delete All SIP PSTN Interworking Parameter Sets (RC;V 5.83)

Lucent Technologies 5ESS
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Delete All SIP PSTN Interworking Parameter Sets (RC/V 5.83)
....................................................................................................................................................................................................................................
Purpose
The SIP PSTN Interworking Parameter Set view (RC/V 5.83) is used
to delete a SIP PSTN interworking parameter set for the packet
trunking application.
When to use
Use this procedure to delete all SIP PSTN interworking parameter sets
.
Related information
Refer to 235-118-258, Recent Change Reference for information on
the RC/V system.
Refer to 235-080-100, Translations Guide, for information on Office
Records (output reports).
Refer to the 235-600-700/750, Input/Output Messages manuals for
additional information on the Input and Output commands.
Admonishments
None.
Before you begin
Required Tools
Supplemental Trunk Line Workstation (STLWS) or Recent
Change and Verify (RC/V) terminal
Access to RC/V Menu Interface
Required Material
The 5ESS
®
switch must be running a 5E16.2 FR6 software
release or later with the SIP for Packet Trunking - NAR feature
software.
Required Information
None.
Required Conditions
All SIP-T packet groups have been deleted on RC/V 5.71
Procedure
............................................................................................................................................................
1
Identify SIP PSTN interworking parameter sets in the SIPPSTN/5893
office records. At the MCC or TLWS type and enter the command:
OP:OFR:FORM=5893;
Deprovisioning
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
6-81

Table of Contents

Related product manuals