OP OFR FORM=5893 PF is printed followed by a printout
of the SIPPSTN/5893 office records.
............................................................................................................................................................
2
Select and prepare terminal for RC/V activities.
Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
3
Type and enter the RC/V form number.
5.83
Result:
Enter Database Operation I=Insert,R=Review,U=Update,
D=Delete:
............................................................................................................................................................
4
Type and enter the delete command.
D
Result:
The SSIP PSTN INTERWORKING PARAMETER SET page is
displayed and the cursor is located at the SET NAME field.
............................................................................................................................................................
5
Type and enter the *SET NAME field value identified in step 1.
............................................................................................................................................................
6
Enter the delete command.
D
Result:
Deleting...form deleted
............................................................................................................................................................
7
Repeat step 4-6 for every SIP PSTN interworking parameter set
identified in step 1.
............................................................................................................................................................
8
Type and enter the previous screen command.
<
Result:
The TRUNK VIEWS page is displayed.
Delete All SIP PSTN Interworking
Parameter Sets (RC/V 5.83)