Restore SCTP Association
....................................................................................................................................................................................................................................
Purpose
This procedure requests the restoral of an SCTP association.
When to use
Use this procedure when the restoral of an SCTP association is
required.
Related information
Refer to the Input Messages Manual, 235-600-700, and the Output
Messages Manual, 235-600-750, for additional information.
Admonishments
None.
Before you begin
Required Tools
• Use of the Master Control Center (MCC) or Supplementary
Trunk Line Workstation (STLWS).
Required Material
• The switch must be running a 5E16.2 FR3 software release or
later with the SIP for Packet Trunking feature software.
Required Information
• Association number to be restored is known.
Required Conditions
• Association status is
CLOSED.
Procedure
............................................................................................................................................................
1
Request a restoral of a specific association :
RST:SCTP,ASSOC=b;
Where:
b = association number
Result:
Reports the result of restoring a specific association to service.
............................................................................................................................................................
2
If the result is NG - INVALID ASSOCIATION ID, then check the
association number on RC/V 33.22. For all others, refer to the Output
Messages Manual, 235-600-750, for additional information.
Maintenance Considerations
....................................................................................................................................................................................................................................
7-68
Lucent Technologies 235-200-118
Issue 3.02B, March 2007