Initiate 105 Test Call
....................................................................................................................................................................................................................................
Purpose
This procedure requests an outgoing 105 test to a far-end 105 testline
over the packet network for a SIP call. Note: This is only supported
for SCTP.
When to use
According to local practices for routine maintenance, use this
procedure to verify the quality of an entire end-to-end connection for
a SIP call.
Related information
Refer to the Input Messages Manual, 235-600-700 and the Output
Messages Manual, 235-600-750, for additional information. Since
there are no Call Instance Codes (CICs) involved in SIP signaling,
only option, Packet Trunk Group (PKTG) is allowed and not Packet
Trunk Group Member Number (PKTGMN).
Admonishments
None
Before you begin
Required Tools
Use of Master Control center (MCC) or Supplementary Trunk
Line Workstation (STLWS).
Required Material
The switch must be running a 5E16.2 FR3 software release or
later with the SIP for Packet Trunking feature software.
Required Information
OPDN
Office Record 5219 for Packet Group
Required Conditions
None required.
Procedure
............................................................................................................................................................
1
Request an outgoing test to a far-end 105 test line:
TST:PATH,OG105,PKTG=f,OPDN=d;
Where:
d = 105 test line DN for desired far-end office
f = Packet group
Maintenance Considerations
....................................................................................................................................................................................................................................