Add New SCTP Association to Connect to a SCTP Far Endpoint
....................................................................................................................................................................................................................................
Purpose
This procedure contains the steps for adding a new SCTP association
to connect to a SCTP far endpoint.
When to use
Use this procedure to connect a new SCTP association to a SCTP far
endpoint.
Related information
Refer to 235-118-258, Recent Change Reference, for information on
the RC/V system.
Refer to 235-080-100, Translations Guide, for information on Office
Records (output reports).
Refer to the 235-600-700/750, Input/Output Messages manuals for
additional information on the Input and Output commands.
Admonishments
None.
Before you begin
Required Tools
• Supplemental Trunk Line Workstation (STLWS) or Recent
Change and Verify (RC/V) terminal
• Access to RC/V Menu Interface
Required Material
• The 5ESS
®
switch must be running a 5E16.2 FR3 software
release with the SIP for Packet Trunking - NAR feature software.
Required Information
• Existing SCTP Far Endpoint name, or IP addresses and SCTP
port to insert new SCTP Far Endpoint
Required Conditions
• None
Procedure
............................................................................................................................................................
1
Examine the SCTPNEPD/5886 office records to select an existing
SCTP near endpoint for the association, or execute the “Add New
SCTP Near Endpoint” (5-99)″ procedure.
Provisioning
....................................................................................................................................................................................................................................
5-102
Lucent Technologies 235-200-118
Issue 3.02B, March 2007