Delete All SCTP Association Sets (RC/V 33.23)
....................................................................................................................................................................................................................................
Purpose
SCTP Association Set (RC/V 33.23) groups associations into
association set for redundancy and load-sharing purposes.
When to use
Use this procedure to delete all association sets.
Related information
Refer to 235-118-258, Recent Change Reference for information on
the RC/V system.
Refer to 235-080-100, Translations Guide, for information on Office
Records (output reports).
Refer to the 235-600-700/750, Input/Output Messages manuals for
additional information on the Input and Output commands.
Admonishments
None.
Before you begin
Required Tools
Supplemental Trunk Line Workstation (STLWS) or Recent
Change and Verify (RC/V) terminal
Access to RC/V Menu Interface
Required Material
The 5ESS
®
switch must be running a 5E16.2 FR3 software
release or later with the SIP for Packet Trunking - NAR feature
software.
Required Information
All Association set names
Required Conditions
All Packet Groups that refer to SCTP association sets have been
deleted on RC/V 5.71
Procedure
............................................................................................................................................................
1
Dump the ASSCSET/5890 office records. At the MCC or TLWS type
and enter the command:
OP:OFR:FORM=5890;
Result:
OP OFR FORM=5890 PF is printed followed by a printout
the ASSCSET/5890 office records.