Procedure
............................................................................................................................................................
1
Select and prepare terminal for RC/V activities.
Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
2
Type and enter the RC/V form number.
33.19
Result:
Enter Database Operation I=Insert,R=Review,U=Update,
D=Delete:
............................................................................................................................................................
3
Type and enter the insert command.
I
Result:
SCTP NEAR ENDPOINT DEFINITION page is displayed and
the cursor is located at NEAR ENDPOINT NAME field.
............................................................................................................................................................
4
Using the RC/V 33.19 form as a guide, type and enter the indicated
values for each field.
• *NEAR ENDPOINT NAME
• #GSM
• #PCR GROUP
• SCTP PORT
• ENDPOINT PARM SET NAME - DEFAULT or customer
defined
............................................................................................................................................................
5
Enter the insert command.
I
Result:
Inserting...form inserted
............................................................................................................................................................
6
Type and enter the previous screen command.
<
Insert SCTP Near Endpoints (RC/V 33.19)
Provisioning
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
5-57