Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
2
Type and enter the RC/V form number.
33.20
Result:
Enter Database Operation I=Insert,R=Review,U=Update,
D=Delete:
............................................................................................................................................................
3
Type and enter the insert command.
I
Result:
The SCTP ASSOCIATION PARAMETER SET page is
displayed and the cursor is located at the PARM SET NAME
field.
............................................................................................................................................................
4
Using the RC/V 33.20 form as a guide, type and enter the parameter
set name in the *PARM SET NAME field.
............................................................................................................................................................
5
Modify the parameters as needed.
• #STREAM NEGO - Indicates whether an association may be
established if the desired number of outbound streams are not
available.
• #PERMANENT - Indicates whether an association shall be
maintained as a permanent connection or not.
• INBOUND STREAMS - Number of offered inbound streams.
• OUTBOUND STREAMS - Number of offered outbound streams.
• MAX PATH RETRANS - Maximum number of retransmissions
of a datagram for an SCTP path before the path is declared
out-of-service.
............................................................................................................................................................
6
Enter the insert command.
I
Result:
Inserting...form inserted
Insert SCTP Association-related Protocol
Parameters (RC/V 33.20)
Provisioning
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies