2
If there are two PHE2s in the processor group, read RC/V 33.4 for the
other channel group, to make sure identical IP interface data was
automatically inserted for it.
............................................................................................................................................................
3
On RC/V 33.3, provision the IP gateway between an external IP
destination and a local IP interface.
Reference:
“Insert IP Routing (RC/V 33.3)” (5-44)
............................................................................................................................................................
4
On RC/V 33.17, use the new IP interface name and each adjacent
router IP address to insert IP ping parameters from the endpoint to the
router(s).
Reference:
“Insert Router Pinging (RC/V 33.17)” (5-47)
............................................................................................................................................................
5
Use EXC:PING, OP:TCPIP:ARPDMP, and OP:TCPIP:RTDMP to
verify reachability of the adjacent IP router from new Ethernet IP
interface.
............................................................................................................................................................
6
Examine the SCTPPARM/5885 office records and select an
appropriate SCTP endpoint parameter set, or do a change/insert
operation on RC/V 33.18 for an existing parameter set to add a new
parameter set.
............................................................................................................................................................
7
On RC/V 33.19, insert the new SCTP Near Endpoint, using the
selected processor group and SCTP parameter set.
Reference:
“Insert SCTP Near Endpoints (RC/V 33.19)” (5-56)
............................................................................................................................................................
8
Type and enter the backup command .
BKUP:ODD;
Result:
BKUP ODD COMPLETED
Add New SCTP Near Endpoint
Provisioning
....................................................................................................................................................................................................................................
5-100
Lucent Technologies 235-200-118
Issue 3.02B, March 2007