Which SIP PSTN parameter set should be used, if any.
Whether local audible ringing should be supplied.
Required Conditions
None
Procedure
............................................................................................................................................................
1
Select and prepare terminal for RC/V activities.
Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
2
If SCTP transport is to be used for SIP signaling to the other office,
examine the ASSCSET/5890 office records to identify the association
set to be used, or execute the “Add New Association Set to Another
Office” (5-105) procedure.
............................................................................................................................................................
3
If UDP transport is to be used:
for SIP signaling to the other office, verify that SFID 700 is
enabled, or execute the Feature Activation (RC/V 8.22)
procedure.
for SIP signaling, examine the UDPPATH/5891 office records to
identify the UDP path to be used, or execute the “Add UDP
Transport for SIP signaling to Another Office” procedure.
............................................................................................................................................................
4
Examine the SIPTPARM/5882 office records and select an appropriate
SIP-T parameter set, or do a change/insert operation on RC/V 5.82 for
an existing parameter set to add a new parameter set.
Reference:
“Insert SIP Parameters (RC/V 5.82)” (5-79)
............................................................................................................................................................
5
Examine the SIPPSTN/5893 office records and select an appropriate
SIP PSTN interworking parameter set, or do a change/insert operation
on RC/V 5.83 for an existing parameter set to add a new parameter
set.
Add New SIP Packet Trunking to Another
Office
Provisioning
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
5-113

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies 5ESS and is the answer not in the manual?

Lucent Technologies 5ESS Specifications

General IconGeneral
BrandLucent Technologies
Model5ESS
CategorySwitch
LanguageEnglish

Related product manuals