Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
2
On RC/V 22.16 for the PSU shelf where the STBY PHE2 exists,
select a channel group number, update the PH TYPE to PHE2, and
update the RMK field.
Reference:
“PH Channel Group Assignment (RC/V 22.16)” (5-19)
............................................................................................................................................................
3
Review RC/V 33.16 to obtain the other PH in the Processor Group.
............................................................................................................................................................
4
Read RC/V 33.1 for the existing channel group in the processor
group, and execute a change/insert operation to change *QUALIFIER
3 and the local IP address.
............................................................................................................................................................
5
Examine the ETHIP/5995 office records and select an unused PHE2
Ethernet Link number.
............................................................................................................................................................
6
Update RC/V 33.16 with the selected PHE2 shelf, position, channel
group, and Ethernet link number.
This operation automatically inserts RC/V 33.4 with the new channel
group, Ethernet IP interface name, and parameters identical to the
existing simplex PHE2 channel group in the processor group.
Shortly after this update, there will be a REPT PSELNK output
indicating that the Ethernet link has been established. (If this does not
happen, debug the Ethernet and router connections until it does.)
If the previously-existing PH in the processor group was not
SERVING (or UNAVAILABLE because either its PHE2 or Ethernet
link were OOS), there will also be an autonomous REPT SERV ROP
output indicating that the new PH in the processor group is
SERVING. Otherwise, the new PH should become NON-SERVING.
............................................................................................................................................................
7
At the MCC or TLWS type and enter the backup command.
BKUP:ODD;
Add a SIP PHE2 to Existing Simplex SIP IP
Processor Group
Provisioning
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
5-119

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies 5ESS and is the answer not in the manual?

Lucent Technologies 5ESS Specifications

General IconGeneral
BrandLucent Technologies
Model5ESS
CategorySwitch
LanguageEnglish

Related product manuals