2
Identify the IP interface(s) names in the IPPING/5884 office records
that have ping data for the old address of the adjacent IP router.
............................................................................................................................................................
3
Select and prepare terminal for RC/V activities.
Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
4
Type and enter the RC/V form number.
33.17
Result:
Enter Database Operation I=Insert,R=Review,U=Update,
D=Delete:
............................................................................................................................................................
5
Type and enter the delete command.
D
Result:
The INTERNET PROTOCOL (IP) PING PARAMETERS page
is displayed and the cursor is located at the INTERFACE
NAME field.
............................................................................................................................................................
6
Using the RC/V 33.17 form as a guide, type and enter the parameters.
• *INTERFACE NAME - name identifying interface
• *IP ADDRESS - address of the access router
............................................................................................................................................................
7
Enter the delete command.
D
Result:
Deleting...form deleted
............................................................................................................................................................
8
Dump the IPROUT/5989 office records. At the MCC or TLWS type
and enter the command:
OP:OFR:FORM=5989
Change IP Address for Adjacent IP Router
Provisioning
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
5-133