Required Information
Association numbers of all provisioned SCTP associations. These
can be obtained either from examining the office records
(FORM=5889), or from the first step of the procedure.
Required Conditions
None
Procedure
............................................................................................................................................................
1
Execute the following command to verify the status of all provisioned
associations:
OP:STATUS,SCTP,ASSOC,ALL;
Result:
The “OP STATUS SCTP ASSOC ALL” output report is printed,
consisting of multiple segments of status information for all
provisioned SCTP associations.
............................................................................................................................................................
2
For each provisioned association number in the output of the previous
step, that is not already in the CLOSED MAN state, execute the
following command.
RMV:SCTP,ASSOC=xxxx,UCL;
where,
xxxx = the association number
Result:
The “RMV SCTP ASSOC=XXXX” output report is printed,
indicating that the association is in the CLOSED MAN state.
The “REPT SCTP ENDPOINTT=yyyyyy autonomous output
report may be printed if the removal of the association caused a
status change for its SCTP near endpoint (from INSERV to
PARTSERV when the first association on the endpoint is
removed, and from PARTSERV to NOSERV when the last
association on the endpoint is removed).
............................................................................................................................................................
3
Repeat steps 1 and 2 until the result from step 1 indicates that all
provisioned SCTP associations are in the CLOSED MAN state.
Disable All SCTP Transport for SIP Packet
Trunking
Deprovisioning
....................................................................................................................................................................................................................................
6-12
Lucent Technologies 235-200-118
Issue 3.02B, March 2007

Table of Contents