Required Material
• The 5ESS
®
switch must be running a 5E16.2 FR3 software
release or later with the SIP for Packet Trunking - NAR feature
software.
Required Information
• Identification of all provisioned UDP paths. These can be
obtained either from examining the office records (FORM=5891),
or from the first step of the procedure.
Required Conditions
• None
Procedure
............................................................................................................................................................
1
Execute the following command to dump the UDPPATH office
records:
OP:OFR:FORM=5891;
Result:
OP OFR FORM=5219 PF is displayed and an output report
is printed, consisting of multiple segments of
status information for all provisioned UDP paths.
............................................................................................................................................................
2
Record the SM and PROCESSOR GROUP for each UDP path.
............................................................................................................................................................
3
For each PROCESSOR GROUP identified in the previous step,
execute the following command:
OP:STATUS,SERV,PCRGRP=xxx-yy;
where,
xxx = the SM number, and
yy = the processor group number.
............................................................................................................................................................
4
Use the RMV:PSUPH command, with the UCL option, for each PSUPH
identified in the OP STATUS SERV output from the previous step.
First remove all the NONSERVING PHs, then the SERVING PHs,
until all processor groups are UNAVAILABLE.
Result:
UDP transport for SIP packet trunking is no longer operational.
Disable All UDP Transport for SIP Packet
Trunking
Deprovisioning
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
6-27

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies 5ESS and is the answer not in the manual?

Lucent Technologies 5ESS Specifications

General IconGeneral
BrandLucent Technologies
Model5ESS
CategorySwitch
LanguageEnglish

Related product manuals