Result:
OP OFR FORM=5887 PF is printed followed by a printout
of the ASSCPARM/5887 office records.
............................................................................................................................................................
2
Select and prepare terminal for RC/V activities.
Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
3
Type and enter the RC/V form number.
33.20
Result:
Enter Database Operation I=Insert,R=Review,U=Update,
D=Delete:
............................................................................................................................................................
4
Type and enter the delete command.
D
Result:
The SCTP ASSOCIATION PARAMETER SET page is
displayed and the cursor is located at the PARM SET NAME
field.
............................................................................................................................................................
5
Using the RC/V 33.20 form as a guide, type and enter the parameter
set name in the *PARM SET NAME field.
............................................................................................................................................................
6
Enter the delete command.
D
Result:
Deleting...form Deleted
............................................................................................................................................................
7
Repeat steps 5 and 6 for every SCTP association parameter set.
............................................................................................................................................................
8
Type and enter the previous screen command.
<
Result:
The INTERNET PROTOCOL VIEWS page is displayed.
Delete All SCTP Association Protocol
Parameter Sets (RC/V 33.20)
Deprovisioning
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
6-45