OP:OFR:FORM=5883;
Result:
OP OFR FORM=5883 PF is printed followed by a printout
of the PCRGRP/5883 office records.
............................................................................................................................................................
2
Dump the ETHIP/5995 office records for each SM-PSU-SHELF-
CHGRP combination from the PCRGRP forms identified above, and
record the INTERFACE NAMEs. At the MCC or TLWS type and
enter the command:
OP:OFR:FORM=5995;
Result:
OP OFR FORM=5995 PF is printed followed by a printout
of the ETHIP/5995 office records.
............................................................................................................................................................
3
Identify the IP INTERFACE NAME for each ETHIP/5995 office
record where the SM, PSU, SHELF and CHGRP matches the SM,
PSU, SHELF and CHGRP in the PCRGRP/5883 office record.
............................................................................................................................................................
4
Dump the IPROUT/5989 office records. At the MCC or TLWS type
and enter the command:
OP:OFR:FORM=5989;
Result:
OP:OFR:FORM=5989 PF is printed followed by a printout
of the IPROUT/5989 office records.
............................................................................................................................................................
5
Identify the IP interface(s) in the IPROUT/5989 office record that
match one of the IP interface names of the SIP PHE2(s) in step 3, and
each destination IP address associated with them.
............................................................................................................................................................
6
Select and prepare terminal for RC/V activities.
Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
7
Type and enter the RC/V form number.
33.3
Delete All IP Routing for SIP UDP Paths
(RC/V 33.3)