group. If it is, use the SW:SERV:PCRGRP command to make it
NON-SERVING.
NOTE: During a SW: (switch), transient calls will be dropped.
............................................................................................................................................................
2
Use the RMV:PSUPH command to put the PHE2 manually OOS.
............................................................................................................................................................
3
Select and prepare terminal for RC/V activities.
Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
4
Update RC/V 33.16 to blank out the shelf/channel
group/position/ethernet link (PHE LINK) data for the PH to be
deleted.
This should automatically result in a deletion of RC/V 33.4 for the
affected channel group (while the IP interface remains on 33.4 for the
other channel group in the processor group), it should not be
necessary/possible to do the 33.4 deletion manually.
............................................................................................................................................................
5
Delete RC/V 33.1 for the channel group being removed from the
processor group.
............................................................................................................................................................
6
On RC/V 22.16 for the PSU shelf, verify that the GRP TYPE of the
affected channel group is NULL.
On RC/V 22.16 screen 2 (or 3), for the appropriate row and group
number, blank out the PH TYPE, AUTO ASSIGN, and RMK fields.
............................................................................................................................................................
7
At the MCC or TLWS type and enter the backup command.
BKUP:ODD;
Result:
BKUP ODD COMPLETED
............................................................................................................................................................
8
Execute the Hardware Degrowth Procedures for the PHE2 and
Ethernet Link.
Refer to 235-105-331, Hardware Change Procedures - Degrowth.
Delete SIP PHE2 from Existing Duplex SIP
IP Processor Group
Deprovisioning
....................................................................................................................................................................................................................................
6-90
Lucent Technologies 235-200-118
Issue 3.02B, March 2007

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies 5ESS and is the answer not in the manual?

Lucent Technologies 5ESS Specifications

General IconGeneral
BrandLucent Technologies
Model5ESS
CategorySwitch
LanguageEnglish

Related product manuals