EasyManua.ls Logo

Lucent Technologies 5ESS - Page 414

Lucent Technologies 5ESS
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
group. If it is, use the SW:SERV:PCRGRP command to make it
NON-SERVING.
NOTE: During a SW: (switch), transient calls will be dropped.
............................................................................................................................................................
2
Use the RMV:PSUPH command to put the PHE2 manually OOS.
............................................................................................................................................................
3
Select and prepare terminal for RC/V activities.
Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
4
Update RC/V 33.16 to blank out the shelf/channel
group/position/ethernet link (PHE LINK) data for the PH to be
deleted.
This should automatically result in a deletion of RC/V 33.4 for the
affected channel group (while the IP interface remains on 33.4 for the
other channel group in the processor group), it should not be
necessary/possible to do the 33.4 deletion manually.
............................................................................................................................................................
5
Delete RC/V 33.1 for the channel group being removed from the
processor group.
............................................................................................................................................................
6
On RC/V 22.16 for the PSU shelf, verify that the GRP TYPE of the
affected channel group is NULL.
On RC/V 22.16 screen 2 (or 3), for the appropriate row and group
number, blank out the PH TYPE, AUTO ASSIGN, and RMK fields.
............................................................................................................................................................
7
At the MCC or TLWS type and enter the backup command.
BKUP:ODD;
Result:
BKUP ODD COMPLETED
............................................................................................................................................................
8
Execute the Hardware Degrowth Procedures for the PHE2 and
Ethernet Link.
Refer to 235-105-331, Hardware Change Procedures - Degrowth.
Delete SIP PHE2 from Existing Duplex SIP
IP Processor Group
Deprovisioning
....................................................................................................................................................................................................................................
6-90
Lucent Technologies 235-200-118
Issue 3.02B, March 2007

Table of Contents

Related product manuals