EasyManua.ls Logo

Lucent Technologies 5ESS - Page 449

Lucent Technologies 5ESS
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
............................................................................................................................................................
2
Check the result and take appropriate action:
If the result is
NG - INVALID ASSOCIATION ID, then examine
the associated office record:
OP:OFR:FORM=5889;
Refer to Translation Guide (TG-5), 235-080-100, for obtaining
office record numbers.
If the result is a status of
CLOSED, then refer to the SIP for Packet
Trunking Corrective Maintenance procedure, Resolve SCTP
Association Problems, 235-200-118, to resolve the problem.
For all others, refer to the Output Messages Manual,
235-600-750, for additional information.
............................................................................................................................................................
3
Stop. You have completed this procedure.
Procedure to Obtain Status
of All Associations
............................................................................................................................................................
1
Request a status report for all associations:
OP:STATUS,SCTP,ASSOC,ALL;
Result:
Generates a status report of all associations.
............................................................................................................................................................
2
Check the result and take appropriate action:
If the result of any of the associations is a status of
CLOSED, then
refer to the SIP for Packet Trunking Corrective Maintenance
procedure, Resolve SCTP Association Problems, 235-200-118, to
resolve the problem.
For all others, refer to the Output Messages Manual,
235-600-750, for additional information.
............................................................................................................................................................
3
Stop. You have completed this procedure.
Request SCTP Association Status
Maintenance Considerations
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
7-13
E ND OF S TEPS
............................................................................................................................................................
E ND OF S TEPS
.........................................................................................................................................................................................................................................................

Table of Contents

Related product manuals