Check the result and take appropriate action:
• If the result is
NG - INVALID ASSOCIATION ID, then examine
the associated office record:
OP:OFR:FORM=5889;
Refer to Translation Guide (TG-5), 235-080-100, for obtaining
office record numbers.
• If the result is a status of
CLOSED, then refer to the SIP for Packet
Trunking Corrective Maintenance procedure, Resolve SCTP
Association Problems, 235-200-118, to resolve the problem.
• For all others, refer to the Output Messages Manual,
235-600-750, for additional information.
............................................................................................................................................................
3
Stop. You have completed this procedure.
Procedure to Obtain Status
of All Associations
............................................................................................................................................................
1
Request a status report for all associations:
OP:STATUS,SCTP,ASSOC,ALL;
Result:
Generates a status report of all associations.
............................................................................................................................................................
2
Check the result and take appropriate action:
• If the result of any of the associations is a status of
CLOSED, then
refer to the SIP for Packet Trunking Corrective Maintenance
procedure, Resolve SCTP Association Problems, 235-200-118, to
resolve the problem.
• For all others, refer to the Output Messages Manual,
235-600-750, for additional information.
............................................................................................................................................................
3
Stop. You have completed this procedure.
Request SCTP Association Status
Maintenance Considerations
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
7-13
E ND OF S TEPS
............................................................................................................................................................
E ND OF S TEPS
.........................................................................................................................................................................................................................................................

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies 5ESS and is the answer not in the manual?

Lucent Technologies 5ESS Specifications

General IconGeneral
BrandLucent Technologies
Model5ESS
CategorySwitch
LanguageEnglish

Related product manuals