Check the result and take appropriate action:
• If the result is
NG - INVALID ASSOCIATION SET, then examine
the associated office record:
OP:OFR:FORM=5890;
Refer to Translation Guide (TG-5), 235-080-100, for obtaining
office record numbers.
• For all others, refer to the Output Messages Manual,
235-600-750, for additional information.
............................................................................................................................................................
3
Stop. You have completed this procedure.
Request SCTP Association Set Status
Maintenance Considerations
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
7-15
E ND OF S TEPS
.........................................................................................................................................................................................................................................................