Related information
Refer to the Input Messages Manual, 235-600-700, and the Output
Messages Manual, 235-600-750, for additional information.
Admonishments
None
Before you begin
Required Tools
• Use of Master Control Center (MCC) or Supplementary trunk
Line Workstation (STLWS).
Required Material
• The switch must be running a 5E16.2 FR3 software release or
later with the SIP for Packet Trunking feature software.
Required Information
• Office Record 5880 that lists the GSM associated with the
identified QPipe.
Required Conditions
• None required.
Procedure
............................................................................................................................................................
1
Request the status of the GQPH QPipe:
OP:STATUS,GQPHPIPE,QPIPE=a-b-c-d-e;
Where:
a = Global switch module number
b = Packet switch unit 2 number
c = PSU2 shelf number
d = GQPH channel group number
e = QLPS network number
Result:
Examine the output. If any QPipes are not in the ACT state, then
CONTINUE with this procedure. Otherwise, EXIT this
procedure.
• If the state is
OOS-DACT, CONTINUE this procedure.
• If the state is
OOSF-CM, SKIP to Step 3.
• If the state is
OOSF-PH, SKIP to Step 4.
Resolve GQPH QPipe Problems
Maintenance Considerations
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
7-45