2
If the status is CLOSED ENDPT, then the problem is with the SCTP near
endpoint of the association. Refer to the SIP for Packet Trunking
Corrective Maintenance procedure, Resolve SCTP Near Endpoint,
235-200-118.
............................................................................................................................................................
3
If the status is CLOSED ERROR, first remove the association:
RMV:SCTP,ASSOCIATION=a[,UCL];
Where:
a = association number
Result:
Observe COMPLETED output message.
............................................................................................................................................................
4
After the association was successfully removed, then restore it:
RST:SCTP,ASSOCIATION=a;
Where:
a = association number
Result:
If the association is still CLOSED ERROR, the problem is most
likely with the far end of the association or IP network in
between or outside of the 5ESS
®
switch.
............................................................................................................................................................
5
Stop. You have completed this procedure.
Resolve SCTP Association Problems
Maintenance Considerations
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
7-65
E ND OF S TEPS
.........................................................................................................................................................................................................................................................