Related information
Refer to the Input Messages Manual, 235-600-700, and the Output
Messages Manual, 235-600-750, for additional information.
Admonishments
Unconditionally removing an endpoint can be service-affecting
causing the shutdown of traffic.
Before you begin
Required Tools
• Use of the Master Control Center (MCC) or Supplementary
Trunk Line Workstation (STLWS).
Required Material
• The switch must be running a 5E16.2 FR3 software release or
later with the SIP for Packet Trunking feature software.
Required Information
• Near endpoint name to be recovered is known.
Required Conditions
• Near endpoint status is
NOSERV or OOS due to a status request or
the autonomous
REPT SCTP NEAREPT.
Procedure
............................................................................................................................................................
1
Obtain a detail status report of endpoint, if the status is not already
known:
OP:STATUS,SCTP,NEAREPT=a,DETAIL;
............................................................................................................................................................
2
If the status is OOS MAN, restore the endpoint:
RST:SCTP,NEAREPT=a;
Where:
a = near endpoint name
Result:
If the endpoint remains OOS, then refer to the SIP for Packet
Trunking Corrective Maintenance procedure, Restore SCTP Near
Endpoint, 235-200-118.
Resolve SCTP Near endpoint Problems
Maintenance Considerations
....................................................................................................................................................................................................................................
7-72
Lucent Technologies 235-200-118
Issue 3.02B, March 2007