EasyManua.ls Logo

Lucent Technologies 5ESS - Page 508

Lucent Technologies 5ESS
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Related information
Refer to the Input Messages Manual, 235-600-700, and the Output
Messages Manual, 235-600-750, for additional information.
Admonishments
Unconditionally removing an endpoint can be service-affecting
causing the shutdown of traffic.
Before you begin
Required Tools
Use of the Master Control Center (MCC) or Supplementary
Trunk Line Workstation (STLWS).
Required Material
The switch must be running a 5E16.2 FR3 software release or
later with the SIP for Packet Trunking feature software.
Required Information
Near endpoint name to be recovered is known.
Required Conditions
Near endpoint status is
NOSERV or OOS due to a status request or
the autonomous
REPT SCTP NEAREPT.
Procedure
............................................................................................................................................................
1
Obtain a detail status report of endpoint, if the status is not already
known:
OP:STATUS,SCTP,NEAREPT=a,DETAIL;
............................................................................................................................................................
2
If the status is OOS MAN, restore the endpoint:
RST:SCTP,NEAREPT=a;
Where:
a = near endpoint name
Result:
If the endpoint remains OOS, then refer to the SIP for Packet
Trunking Corrective Maintenance procedure, Restore SCTP Near
Endpoint, 235-200-118.
Resolve SCTP Near endpoint Problems
Maintenance Considerations
....................................................................................................................................................................................................................................
7-72
Lucent Technologies 235-200-118
Issue 3.02B, March 2007

Table of Contents