Generates the service selection switch report for a specific
PSU2.
............................................................................................................................................................
2
Check results and take appropriate action:
If the switch
FAILED, then probably a software error occurred.
SEEK TECHNICAL ASSISTANCE according to local procedures
for the affected PH.
If the switch is
DENIED, then a wrong identifier was entered.
Retry with the correct identifier.
If the response is
ELNK DOWN, then determine the cause of the
Ethernet link going down and repair it, if possible.
If the response is
PING FAILURE, then the problem is most likely
with the adjacent IP router external to the 5ESS
®
switch.
............................................................................................................................................................
3
Stop. You have completed this procedure.
Request Manual Service Selection Switch
Maintenance Considerations
....................................................................................................................................................................................................................................
7-84
Lucent Technologies 235-200-118
Issue 3.02B, March 2007
E ND OF S TEPS
.........................................................................................................................................................................................................................................................