_SCON – Speed control Subject area • 61Parameter Description MC6000/7000
_ENCD
_VAL
Index
_VFCON
_PMOD
_KPAD
Contents
Introduction
_SIO
_SCTY
_REF
_SYS
_IO1
_IO2
_CAN
_OPT1
_MOT
_CONF
_TCON
_SCON
_PCON
368-FCQB - Factor B for calculation of reduced q-current in FSB
Source:
Function: The constants QA and QB of the flux control determine the torque reduction in the field
weakening range.
364-FCTLG - Lag time of flux control
Source:
Function: Lag time of flux control (I-component of PI controller).
128-FCTS - Sampling time of voltage and flux control circuit
Source:
Function: Sampling time of flux control
CAUTION - Do not change parameter!
Parameter only for development and service purposes
Values:
Minimum Maximum Factory set. Unit MODE SMARTCARD Type
0 1.53552e+06 45640 A R5W5 DRIVE FLOAT32
CAUTION - Do not change parameter!
Parameter only for development and service purposes
Values:
Minimum Maximum Factory set. Unit MODE SMARTCARD Type
0 1 0.06397 s R5W5 DRIVE FLOAT32
CAUTION - Do not change parameter!
Parameter only for development and service purposes
Values:
Minimum Maximum Factory set. Unit MODE SMARTCARD Type
0.00025 0.0005 0.00025 s R5W15 ALL FLOAT32