66 • Subject area _SCON – Speed control Parameter Description MC6000/7000
_ENCD
_VAL
Index
_VFCON
_PMOD
_KPAD
Contents
Introduction
_SIO
_SCTY
_REF
_SYS
_IO1
_IO2
_CAN
_OPT1
_MOT
_CONF
_TCON
_SCON
_PCON
371-VCTS - Sampling time of voltage regulator (only MC6000)
Source:
Function: Sampling time of voltage regulator (display only)
372-VCVLM - Limitation of control deviation of voltage regulator
Source:
Function: Limitation of control deviation of voltage regulator
374-VCVRF - Voltage reserve in voltage control loop
Source:
Function: MC7000 Voltage reserve in voltage control loop
MC6000: Voltage reference of voltage control loop
CAUTION - Do not change parameter!
Parameter only for development and service purposes
Values:
Minimum Maximum Factory set. Unit MODE SMARTCARD Type
0.0004992 0.0004992 0.0004992 s R5W7 DRIVE FLOAT32
CAUTION - Do not change parameter!
Parameter only for development and service purposes
Values:
Minimum Maximum Factory set. Unit MODE SMARTCARD Type
0 25 1 V R5W5 DRIVE FLOAT32
CAUTION - Do not change parameter!
Parameter only for development and service purposes
Values:
Minimum Maximum Factory set. Unit MODE SMARTCARD Type
0 1000 0 V R5W5 DRIVE FLOAT32