_VFCON – (V/F mode) Subject area • 73Parameter Description MC6000/7000
_ENCD
_VAL
Index
_VFCON
_PMOD
_KPAD
Contents
Introduction
_SIO
_SCTY
_REF
_SYS
_IO1
_IO2
_CAN
_OPT1
_MOT
_CONF
_TCON
_SCON
_PCON
_VFCON – (V/F mode)
34-VFVHZ - Voltage frequency control setting
Function: The parameter determines the rise in the linear voltage/frequency characteristic in the
unit Volts per Hz.
Í 35-VFBST – Boost setting of voltage frequency control
35-VFBST - Voltage frequency control boost setting
Function: The parameter determines the voltage boost at a frequency of 0Hz.
Í 34-VFVHZ – Voltage frequency control setting
CAUTION - Do not change parameter!
Parameter only for development and service purposes
Values:
Minimum Maximum Factory set. Unit MODE SMARTCARD Type
MC7000
0 20 7.6 V R5W5 DRIVE FLOAT32
Note:
For commissioning and test purposes the servocontroller also has a simple voltage/
frequency characteristic voltage frequency control. It is activated with CFCON =
VFCON (_CONF).
CAUTION - Do not change parameter!
Parameter only for development and service purposes
Values:
Minimum Maximum Factory set. Unit MODE SMARTCARD Type
MC7000
0 50 2 V R5W5 DRIVE FLOAT32
VFBST
U [V]
VFVHZ
f [Hz]