_KPAD – KeyPad KP100 Subject area • 81Parameter Description MC6000/7000
_ENCD
_VAL
Index
_VFCON
_PMOD
_KPAD
Contents
Introduction
_SIO
_SCTY
_REF
_SYS
_IO1
_IO2
_CAN
_OPT1
_MOT
_CONF
_TCON
_SCON
_PCON
In a reset the parameter list is checked for validity and the dependent parameters are calculated. This
update of the parameter list takes a short time.
To avoid the delay in starting the drive, the reset can be triggered manually beforehand (above option
1 or 3).
6-PNUM - Activate/deactivate parameter number display of KP100
Source: Parameter Number
Function: Activate/deactivate display of parameter number
4-PROG - Special functions
Source: Program Functions
Function: Selection of special program functions
Values:
Minimum Maximum Factory set. Unit MODE SMARTCARD Type
OFF ON OFF – R4W4 SYSTM USIGN8
Note:
When the parameter number display is deactivated the KeyPad display indicates
whether a parameter can only be displayed, or also edited (-S- or -E-).
Values:
Minimum Maximum Factory set. Unit MODE SMARTCARD Type
0 65535 2 – R4W4 SYSTM USIGN16
Setting Function
1 Reset all parameters to factory defaults
2 Normal setting, no function.
111 Reset serial interface with current value of para-
meter SBAUD
Note:
Other values are intended for special functions. Caution!