_SCON – Speed control
452-10PC - Setup mode: Number of overshoots with amplitude >10% in first
overshoot range (only MC6000)
Source: 10 Percent
Function: For speed controller setup mode (SETUP function\): Number of overshoots with an ampli-
tude greater than 10 percent of the first overshoot.
Parameter only on MC6000.
454-1OVER - Setup mode: First overshoot range (only MC6000)
Source: First Overshoot
Function: For speed controller setup mode (SETUP function\): First overshoot
Parameter only on MC6000.
366-FCG - Flux control gain
Source:
Function: Flux control gain (P-component of PI controller).
367-FCQA - Factor A for calculation of reduced q-current in FSB
Source:
Function: The constants QA and QB of the flux control determine the torque reduction in the field
weakening range.
Values:
Minimum Maximum Factory set. Unit MODE SMARTCARD Type
02550 – R3W15 ALL USIGN8
Values:
Minimum Maximum Factory set. Unit MODE SMARTCARD Type
-32764 32764 0 rpm R4W15 ALL INT32Q16
CAUTION - Do not change parameter!
Parameter only for development and service purposes
Values:
Minimum Maximum Factory set. Unit MODE SMARTCARD Type
0 8191 514.200012 – R5W5 DRIVE FLOAT32
CAUTION - Do not change parameter!
Parameter only for development and service purposes
Values:
Minimum Maximum Factory set. Unit MODE SMARTCARD Type
0 31 2.432 A R5W5 DRIVE FLOAT32