Ex: Migration with addition for RAID5 virtual disk
The figure below shows an example of adding a single 146GB HDD to a RAID5 virtual disk
configured with three 146GB HDDs.
146GB 146GB
146GB
146GB
146GB 146GB
146GB
146GB
Virtual disk(RAID5)
Virtual disk(RAID5)
Before execution
Capacity=292GB
Before execution
Capacity=438GB
Execute Migratioon with addition
IMPORTANT:
Note the following for the Reconstruction:
Be sure to make backup copy of data and perform Consistency
Check before starting Reconstruction.
The Reconstruction is disabled in the configuration where several
virtual disks are defined in one disk group
During Reconstruction, the processing rate is decreased due to
heavy load.
The Reconstruction can be performed for the degraded virtual disk.
However, it is recommended to execute Rebuild to recover the
virtual disk, then execute Reconstruction.
During Reconstruction, do not shutdown or reboot the server.
In some configuration, Background Initialize may start
automatically upon completion of Reconstruction.