Operation and Maintenance
670
Ether Test
(1) Outline
Internal loop back test
This test uses the internal loopback function in the Ether host adapter to loopback packets in
the host adapter and checks the transmission/reception on the host adapter is properly
done.
When transmission and reception are repeated 1000 times, the test round counts up one.
(Caution)
Ensure to disconnect the LAN cable from the LAN card before starting the test.
Test packet may leak to the network.
(2) Message
1. Standard message
Message Content
Internal Loopback Test.
Interface Name = xx
Hardware Address = xx
Length of data = xx
Count of packets per cycle = xx
Transfer Rate = xx
Test data = xx
Test information is displayed.
Test start. Test is started.
Test terminate. Test ended.
2. Error message
Message Content
Data unmatch error.
(offset of send external data : xx)
Expected data is as follows.
xx: xx xx xx …
Actual data is as follows.
xx: xx xx xx …
Data mismatching occurred.
Ether operation error occurred.
API status : xx
Driver status : xx
This indicates an error occurred on operation for
the host adapter.
API status : Refer to Appendix B (2) API status.
Driver status : Refer to Appendix B (1) errno.
Controller registers : xx xx xx … Value of controller register is displayed.