Hardware
372
Setting level of Universal RAID Utility and the setting value
Item Setting level of URU Setting value
High 90
Middle 50
Rebuild Priority
Rebuild Rate (WebBIOS)
Low 10
High 90
Middle 50
Patrol Read Priority
Patrol Read Rate (WebBIOS)
Low 10
High 90
Middle 50
Consistency Check Priority
CC Rate (WebBIOS)
Low 10
NOTE:
WebBIOS can set BGI Rate (Background Initialize Priority). But
Universal RAID Utility cannot set it.
Universal RAID Utility can set Initialization Priority. But, Internal
RAID Controller does not have the function of the setting of
Initialization Priority. Therefore, Universal RAID Utility does not
display [Initialization Priority] in the property of RAID Controller.
Also, it will fail that you change the Initialization Priority by
raidcmd.