432
(1) Server Health
Display server status.
Name : Server name
Power : Power status
Display (value) Description
Off DC power of all Server is OFF
On DC power of at least 1 Server is ON.
Health : Overall server status
(Severity Level:Normal < Non-Critical < Critical)
Display (value) Description
Normal No failure occurrence, or Correctable Error only.
Non-Critical Recoverable Error occurrence. Maintenance is
required inside the server.
Critical Fatal Error occurrence. Maintenance is required
inside the server.
Status : Server status
Display (value) Description
Stopped Stopped status.
BIST Running BIST Running status.
Initializing Boot-up (mounting) in progress status
EFI Manager Booted EFI Manager Booted status
OS or T&D Starting OS or T&D Starting status
T&D Running T&D Running status
OS Running OS Running status
Stopping Shutdown (mounting) in progress status
Handling Fault Handling Fault status
Handling DP Handling DP status
Power On Failed Stopped status with power-on failure
(2) Resource Health
Display resource status.
Name : Resource name
Power : Resource power status
Display (value) Description
Off DC power of all Servers is OFF(DC OFF)
On DC power of at least 1 Server is ON(DC ON)
Health : Overall resource status
Display (value) Description
Normal No failure, or detection of Correctable Errors only.
Non-Critical Recoverable Error occurrence. Maintenance is
required inside the server.
Critical Fatal Error occurrence. Maintenance is required
inside the server.