Remote Commands
R&S
®
FSW
1055User Manual 1173.9411.02 ─ 43
Manual operation: See "Using the power sensor as an external trigger"
on page 378
See "Trigger Source" on page 482
See "Free Run" on page 482
See "External Trigger 1/2/3" on page 482
See "Video" on page 483
See "IF Power" on page 483
See "Baseband Power" on page 483
See "RF Power" on page 483
See "Power Sensor" on page 484
See "Time" on page 484
TRIGger[:SEQuence]:TIME:RINTerval <Interval>
This command defines the repetition interval for the time trigger.
Parameters:
<Interval> 2.0 ms to 5000
Range: 2 ms to 5000 s
*RST: 1.0 s
Default unit: S
Example:
TRIG:SOUR TIME
Selects the time trigger input for triggering.
TRIG:TIME:RINT 50
The sweep starts every 50 s.
Manual operation: See "Repetition Interval" on page 485
14.7.4.2 Configuring Gated Measurements
[SENSe:]SWEep:EGATe............................................................................................... 1055
[SENSe:]SWEep:EGATe:AUTO..................................................................................... 1056
[SENSe:]SWEep:EGATe:CONTinuous:PCOunt...............................................................1057
[SENSe:]SWEep:EGATe:CONTinuous:PLENgth..............................................................1057
[SENSe:]SWEep:EGATe:CONTinuous[:STATe]................................................................1057
[SENSe:]SWEep:EGATe:HOLDoff..................................................................................1058
[SENSe:]SWEep:EGATe:LENGth...................................................................................1058
[SENSe:]SWEep:EGATe:LEVel:RFPower....................................................................... 1058
[SENSe:]SWEep:EGATe:LEVel[:EXTernal<port>]............................................................ 1059
[SENSe:]SWEep:EGATe:POLarity..................................................................................1059
[SENSe:]SWEep:EGATe:SOURce................................................................................. 1060
[SENSe:]SWEep:EGATe:TYPE......................................................................................1060
[SENSe:]SWEep:EGATe <State>
This command turns gated measurements on and off.
Setting Basic Measurement Parameters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S FSW Series and is the answer not in the manual?

R&S FSW Series Specifications

General IconGeneral
BrandR&S
ModelFSW Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals