Common Analysis and Display Functions
R&S
®
FSW
536User Manual 1173.9411.02 ─ 43
CALCulate<n>:MARKer<m>:FUNCtion:NOISe:RESult? on page 1185
Marker State................................................................................................................536
Marker Type................................................................................................................ 536
Noise Measurement State...........................................................................................536
Switching All Noise Measurement Off.........................................................................536
Marker State
Activates or deactivates the marker in the diagram.
Remote command:
CALCulate<n>:MARKer<m>[:STATe] on page 1155
CALCulate<n>:DELTamarker<m>[:STATe] on page 1153
Marker Type
Toggles the marker type.
The type for marker 1 is always "Normal", the type for delta marker 1 is always "Delta".
These types cannot be changed.
Note: If normal marker 1 is the active marker, switching the "Mkr Type" activates an
additional delta marker 1. For any other marker, switching the marker type does not
activate an additional marker, it only switches the type of the selected marker.
"Normal"
A normal marker indicates the absolute value at the defined position
in the diagram.
"Delta"
A delta marker defines the value of the marker relative to the speci-
fied reference marker (marker 1 by default).
Remote command:
CALCulate<n>:MARKer<m>[:STATe] on page 1155
CALCulate<n>:DELTamarker<m>[:STATe] on page 1153
Noise Measurement State
Activates or deactivates noise measurement for the marker in the diagram.
This function is only available for normal markers.
If activated, the marker displays the noise power density measured at the position of
the marker.
For details see Chapter 9.3.4.2, "Measuring Noise Density (Noise Meas Marker)",
on page 534.
Remote command:
CALCulate<n>:MARKer<m>:FUNCtion:NOISe[:STATe] on page 1185
CALCulate<n>:MARKer<m>:FUNCtion:NOISe:RESult? on page 1185
Switching All Noise Measurement Off
Deactivates noise measurement for all markers.
Remote command:
CALCulate<n>:MARKer<m>:FUNCtion:NOISe[:STATe] on page 1185
Marker Usage

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S FSW Series and is the answer not in the manual?

R&S FSW Series Specifications

General IconGeneral
BrandR&S
ModelFSW Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals