Error Name/Error Condition/Major Cause/Solution
1. Turn the main power OFF/ON.
2. Replace the BiCU (PCB16).
Error Name/Error Condition/Major Cause/Solution
MACARON Operating Mode Setting Error (IM 550F/600F/600SRF) / BREIT
Operating Mode Setting Error (P 800/801)
The mode setting error of MACARON (IM 550F/600F/600SRF) / BREIT (P
800/801) is detected during the startup operation of the engine (when the main
power is turned on or when the machine returns from energy save mode).
1. Turn the main power OFF/ON.
2. Replace the BiCU (PCB16).
Error Name/Error Condition/Major Cause/Solution
IOB (PCB17) Startup Error
The signal to indicate the IOB (PCB17) has started up was not detected within 4
seconds.
• FFC defective or disconnected
• IOB (PCB17) defective
• IPU defective
1. Turn the main power OFF/ON.
2. Reconnect the FFC between IPU and IOB (PCB17).
3. Replace the FFC between IPU and IOB (PCB17).
4. Replace the IOB (PCB17).
5. Replace the IPU.
Error Name/Error Condition/Major Cause/Solution
IOB (PCB17)Communication Error: Reset Error
Communication reset control and error recovery control does not complete
properly.
• FFC not properly connected
• FFC defective
• IOB (PCB17) defective
• BiCU (PCB16) defective
1. Turn the main power OFF/ON.
2. Turn the main power OFF, reconnect the FFC between BiCU (PCB16) and
IOB (PCB17), and then turn the main power ON.