TM Palletizing Operator User’s Manual Product Version: 1.0 / Document Version: 1.0 93
The 8mm compressed air tube is NOT included in the product delivery. Users should
prepare for this tool before connecting external compressed air supply.
The compressed air quality is required in accordance with ISO 8573-1:2010 [7:4:4]
5.3.1 Considerations for Connecting External Compressed Air
Pressure switch can detect and display the pressure value of external compressed air. Users may also
enable air pressure sensor detection in Advanced Setting under TMflow software. Users may set the
parameters for air source sensor detection to pause the system if the message “Air Source Pressure Too
Low” appears (refer to Num.17 in 6.6.1 Advanced1_General_Parameters).
The default value of external compressed air pressure is 0.5MPa (5 bar). Users may adjust the pressure
detect value based on the relation between the supplied compressed air and the object to be gripped.
The output air pressure is adjustable through filter regulator.
The output air pressure is shown on the pressure gauge.
The operating pressure (of vacuum generator) is between 2.0 and 6.0 bar.
Figure 65: Filter Regulator and Pressure Gauge location
Pressure Gauge
Filter Regulator
Pressure Detect Sensor