Note: Before using the new fuser, the system administrator must update the NVM width
setting values to match the specific width used for this fuser.
The following table defines the media sizes, width ranges, and default NVM values that can be set for
the fuser.
Table 2.1 Bypass Connector Used for Default Paper Width NVM Settings
Range
Number
Bypass
Connector Media Size
Width Range
NVM Default Value
1 None All paper widths 98.0–330.2 mm
(3.858–13.0 in.)
980–3302
2 Black Resistor
Type
• A4 LEF
• Letter LEF
• A4 SEF
• Letter SEF
• A3 SEF
• 11 x 17 in.
SEF
270.4–298.0 mm
(9.84–11.69 in.)
2704–2980
3 Blue Type SRA3
12 in.
13 in.
300.0–330.2 mm
(12.09–13.00 in.)
3000–3302
Note: Refer to the System Administrator Guide for the procedure on how to reset NVM settings
for other widths not shown in this table.
Changing the Fuser Width ID
The press is installed with a default standard fuser type that is suitable for all media sizes (paper
widths). However, when removing the fuser module, you can optimize its life and maintain the system
image quality output by attaching a jumper connector to the fuser assembly that identifies the
specific paper width range to use. For assistance and information on changing the fuser width ID,
contact Customer Support.
If you plan to print jobs using a specific paper width, use this procedure to attach the bypass
connector for that fuser to the fuser assembly. This identifies to the system that a different fuser is
being used and only certain paper widths will be allowed to print.
The fuser types available are:
• 11 inch (A4, Letter SEF) width fuser
• 12 inch (A3 SEF, A4, Letter LEF, 304.8 mm) width fuser
• 13 inch (SRA 3, 330.2 mm) width fuser
258
Xerox
®
Versant
®
4100 Press
User Documentation
Working With