Solution
• Check the status of the consumables and supplies by pressing the Home button on the control
panel. Refer to Checking the Status of Consumables.
• Run the Performing the Clean Toner Procedure.
• Shake or replace the affected dry ink/toner cartridge. Refer to Replacing a Dry Ink/Toner
Cartridge.
• Determine if a drum cartridge is contaminated or light shocked by running a set of halftone
test patterns to identify which color is affected:
– Go to www.xerox.com/VERSANT_4100docs and download the Halftone Test Pattern PDF.
– Print several sets of the Halftone Test Pattern PDF.
– Determine which color drum is affected.
– Swap or replace the required drum cartridge. Refer to Replacing a Drum Cartridge.
• Refer to Uneven Density or Mottle.
IImmaaggee--oonn--PPaappeerr RReeggiissttrraattiioonn
Problem
The entire image on the printed output is misregistered, shifted, skewed, or crooked.
300