Option or
Setting
Default
Value
Adjust-
ment
Step
Incre-
ments
Available
Range
Recommended Incremental
Adjustment
Fuser
Temperature
Adjustment
0 1 -10 to 10° C or 2 °
Fuser Speed
Adjustment
0.0 0.1 -5.0 to 5.0 % 0.1%
Aligner Roll
Pressure
0 1 -40 to 40 Pulse 5 or 10
Regi-Loop 0.0 0.3 -3.0 to 3.0 mm 0.3 mm
Alignment
Profile
Default Distinct
Selections
Available
Available
selections will
be based on
the Profiles
created by the
user
Determined by test print output
Fold Adjustment
Profile
Default Distinct
Selections
Available
Available
selections will
be based on
the Profiles
created by the
user
Determined by test print output
Pre Gate Roll
Adjustment
System
Default
Distinct
Selections
Available
System Default
On
Off