EasyManua.ls Logo

Cisco MCS-7825-H3-IPC1 - Page 961

Cisco MCS-7825-H3-IPC1
974 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-21
Cisco Unified Communications Manager Managed Services Guide
OL-22523-01
Chapter 9 Vendor-Specific Management Information Base
Hewlett Packard MIBs
Rebuilding (7) Indicates that the
logical drive is currently doing
Automatic Data Recovery. During
Automatic Data Recovery, fault
tolerance algorithms restore data to
the replacement drive.
Wrong Drive (8) Indicates that the
wrong physical drive was replaced
after a physical drive failure.
Bad Connect (9) Indicates that a
physical drive is not responding.
Physical Drive
1
CPQIDA-MIB
1.3.6.1.4.1.232.3.2.5.1.1.6
cpqDaPhyDrvStatus
Clearing Value = 2
The following values are valid for
the physical drive status:
other (1) Indicates that the
instrument agent does not
recognize the drive. You may need
to upgrade your instrument agent
and/or driver software.
ok (2) Indicates the drive is
functioning properly.
failed (3) Indicates that the drive is
no longer operating and should be
replaced.
predictiveFailure(4) Indicates that
the drive has a predictive failure
error and should be replaced.
System Fan CPQHLTH-MIB
1.3.6.1.4.1.232.6.2.6.4
cpqHeThermalSystem
FanStatus
Clearing Value = 2
This value will be one of the following:
other(1) Fan status detection is not
supported by this system or driver.
ok(2) The fan is operating properly.
degraded(2) A redundant fan is not
operating properly.
failed(4) A non-redundant fan is
not operating properly.
Table 9-13 HP Hardware Status Messages, MIBs and OIDs, MIB Object Names and Clearing Values, and
Object Responses (continued)
Cisco Unified CM Release 6.x
MCS-78xx Status MIB and OID
MIB Object Name and
Clearing Value Object Response

Table of Contents

Related product manuals