95
M2.0-1055-102
HYDRAULIC
Accessory Clamp Set-Up
6. Use the Operator Menu to set pressure regulator
tag pressures to the desired levels. This menu is
only available when F20 and F21 are enabled. Re-
fer to Figure 15414.
7. Verify force output of clamp during operation.
8. If faster clamp operation is desired, note time (sec-
onds) to cycle clamp. Increase F13 setting in
1 GPM increments. If time does not decrease, re-
lief pressures have been reached. Reduce flow to
previous setting.
Figure 15414
Relief Pressure Setup Notes:
1 The user relief pressure setup feature must
be turned on in the features menu for this
feature to be visible.
2 Tag refers to which function the pressure is
applied to.
3 A re-key is required if any of the relief pres-
sures are changed and you want to save
those changes.