LUBRICATION & ADJUSTMENT
Componentry
66
M1.0-1055-071
01 Rev. 3/07
RVA
Relief Valve Accessory
Location: mast manifold.
Purpose: limit maximum tilt and accessory pressure
(independent from raise).
Data: adjusted to 17237 Kpa (2500 psi) at vendor.
Adjustment: none required.
RVM
Relief Valve Mast
Location: mast manifold.
Purpose: limit maximum lift pressure for raise.
Data: adjusted to 23442 Kpa (3400 psi) at vendor.
Adjustment: none required.
SSS
Sequence Select Switch
Location: right side of multi-task handle casting.
Purpose: allows 4th and 5th function selection.
Data: printed circuit board mounted push button.
Adjustment: none required.
Figure 15941
Figure 15944
Figure 15937
Crown 2007 PF15674-22 Rev. 3/07