LUBRICATION & ADJUSTMENT
Componentry
70
 M1.0-1055-075
01 Rev. 3/07
SVA2A
Second Accessory Solenoid
Location: mast manifold.
Purpose: provide hydraulic flow path for second ac-
cessory function.
Data: coil energized by Access 7 when second acces-
sory function selected via POT3 and pressing SSS at
the same time. Coil resistance 28.8 ohm. Coil voltage
24VDC regardless of battery voltage.
Adjustment: none required.
SVA2B
Second Accessory Solenoid
Location: mast manifold.
Purpose: provide hydraulic flow path for second ac-
cessory function.
Data: coil energized by Access 7 when second acces-
sory function selected via POT3 and pressing SSS at
the same time. Coil resistance 28.8 ohm. Coil voltage
24VDC regardless of battery voltage.
Adjustment: none required.
SVA3
5th Function
Location: part of attachment.
Purpose: 5th function.
Data: none required.
Adjustment: none required.
TBS
Tilt Back Switch
Location: multi-task handle.
Purpose: allows operator to select tilt back function of
hydraulic system.
Data: printed circuit board mounted push button switch
wired normally open.
Adjustment: none required.
Figure 15945
Figure 16056
Figure 15947
Figure 15948
Crown 2007 PF15674-26 Rev. 3/07