51
M1.0-1055-056
LUBRICATION & ADJUSTMENT
Componentry
ECR4
AC/DC Pump Motor Encoder
Location: inside AC/DC pump motor.
Purpose: sense AC/DC pump motor speed.
Data: 11.3VDC, 64 pulses per revolution.
Adjustment: none required.
EDS
Emergency Disconnect Switch
Location: right side of multi-task handle casting.
Purpose: allows disconnection of power in emergency
situation. Resets the emergency disconnect contactor,
removing power from power/control circuitry.
Data: wired normally closed until operator depresses
button, then momentarily opens.
Adjustment: none required.
Figure 15888