EasyManua.ls Logo

Crown RC 5500 series - Capacitance

Crown RC 5500 series
691 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ELECTRICAL
Event Codes
212
M4.8-1055-002
03 Rev. 10/09
Capacitance
CAUTION
Due to capacitance voltage present in the ACCESS 3
traction control module and ACCESS 2 hydraulic con-
trol module, whenever performing maintenance which
may permit contact with the bus bars and associated
power cables, discharge the capacitors.
Move truck to a secure non-traffic maintenance
area with a level floor.
Lockout and tagout truck as described in Lockout -
Tagout in this section.
Disconnecting the battery will discharge the capac-
itors. Once the dash display flashes, the capacitors
are discharged. Two alternative methods of dis-
charging these capacitors are to disconnect the
battery and hold the key switch in the "start" posi-
tion for 10 seconds or disconnect the battery and
connect a 200 ohm, 2 watt resistor between the
positive and negative terminals on the controller.
Turn key switch to OFF, remove key.
Crown 2007 PF15665-2 Rev. 10/09

Table of Contents

Related product manuals